PY602/PY602H/PY602S  description


Description


PY602 pressure indicator is a 1/8 DIN or 1/4 DIN, panel-mount, dual 4-digit indicator, which takes the advantage of latest state-of-art technology and comes in small-size, light-weight and in low-power. This pressure indicator has been specifically designed for use with mv/Volt output transducers from different famous manufacturers such as Dynisco, Gefran, ONEhalf20 and so on. Together with the mV/Volt transducers and thermocouple, PY602 Pressure Indicator can be working as the high precision pressure and temperature measurement. PY602 Pressure indicator displays the pressure and temperature and outputs the control relays timely.


PY602/PY602H Indicator Specification

(1)

Display

Dual 4-digit Green and Red LEDs

(2)

Resolution

0.2% FSO ± 1

(3)

LEDs

Out, Alarm-1, Alarm-2, Calibration

(4)

Input Sensibility

2.5mv/V or 3.3 mV/V (automatic selection)

(5)

Sampling Speed

20 per second

(6)

Excitation Voltage

+9 VDC (output to transducer)

(7)

Temperature Input

Thermocouple “E”, “J”, “K”

(8)

All Output Relays

Relay 220V 1A

(9)

Retransmission

4~~20 mA standard current loop

(10)

Communication

RS-485 MODBUS( PY602 Only)

(11)

Alarm Range

0001 – 9999 PSI or Bar (configurable)

(12)

Temperature

0 - 55°C

(13)

Humidity

<= 80% RH

(14)

?Calibration

80% FSO (Full Scale Output)

(15)

Power Supply

110/220VAC or +24VDC (designated while purchasing)

(16)

Size

PY602H: 96mm×48mm×100 mm (W x H x D)
PY602: 96mm x 96mm x 100 mm (W x H x D)

(17)

Panel Cutout

PY602H: 92mm x 46mm (W x H)
PY602: 92mm x 92mm (W x H)

(18)

?Weight

400(Maximum) grams



PY602/PY602H Indicator Panel description

PY602

PY602S

 PY602

 PY602S

PY602H

 PY602H


PY602/PY602H/PY602S Pressure&Temperature Indicator Manual


(1)“OUT” LED turns on when the pressure is not less than the OUT setting value.
“AL-1” LED turns on when the pressure is not less than the AL-1 setting value.
“AL-2” LED keeps reserved.
(2) “CAE” LED truns on when the is pressed for checking the calibration.
(3) PV window displays the actual pressure value.
(4) SV windows displays the OUT setting value.
(5) key: to clear the pressure value when it is under setting and no load is on
(6) key: to check the calibration value (80% of Full Scale Output).
(7) key: to enter the setting mode and to exit the setting mode.
key has longer-time(more than 3 Second) press and shot-time press.
(8) “>” key: shift the digit to be edited
(9)“∧” key: to edit and increase the value

Indicator Model Ordering guide

PY602

Model

Panal Cutout Size

--

96*96

H

96*48

S

48*96

4

Number of Display Digits

Alarms

1

1 Alarm relay

2

2 Alarm relay

3

3 Alarm relay

Retransmission

R

Retransmission

N

No Retransmission

Communication

C

Communication RS-485

Power supply

D

+24VDC

 

 

ENQUIRY